🔍 What Went Wrong

Despite early suspicion of a major DDoS attack, Cloudflare confirmed the issue was entirely internal:

✔ A database permission change
→ produced duplicate entries
→ doubled the size of a Bot Management “feature file”
→ exceeded a memory limit inside Cloudflare’s core proxy.

When the oversized file propagated globally, proxies crashed — causing massive traffic failures across Cloudflare’s network.

🌐 How It Looked to Users

  • Websites behind Cloudflare returned 5xx errors
  • Cloudflare’s own status page appeared down (a coincidence)
  • Login sessions and internal APIs failed
  • Workers KV and Cloudflare Access were partially disrupted

🔁 Why It Was Hard to Diagnose

The system alternated between working and failing every few minutes as different database shards generated “good” or “bad” versions of the feature file.
This intermittent failure appeared to be the result of an active attack.

🛠 How Cloudflare Fixed It

By 14:30 UTC, Cloudflare:

  • Stopped distributing the bad config file
  • Manually deployed a known-good file
  • Restarted core proxy systems
  • Scaled up capacity to handle traffic surges after recovery

All systems were fully restored by 17:06 UTC.

📌 Cloudflare’s Response

Cloudflare has openly acknowledged this as an unacceptable failure, promising:

  • Stricter validation of internal config files
  • More kill switches and fail-safes
  • Better proxy module error handling
  • Improved ClickHouse permission rollout processes

🧠 Why This Matters

Cloudflare sits at the center of global Internet infrastructure.
When it fails — even for minutes — the ripple effect is enormous.

Incidents like this reinforce the importance of:

  • Defense-in-depth, even against internal changes
  • Zero-trust architecture inside critical infrastructure
  • Global kill switches for high-impact systems
  • Configuration file sanitization, just as with user input

Blog

Microsoft 5 min read

Keys, Tenants and Trust: two Microsoft cloud incidents that call for action this week

Two Microsoft cloud services were hit in November 2026, and each needs a different response. In Azure API Management (APIM) Classic, attackers exploited a flaw to steal stored secrets, and Norway's security agency says those secrets should be treated as exposed. In Entra Connect Health, attackers accessed tenant metadata and administrator email addresses, but Microsoft says passwords and authentication tokens were not exposed.

Security 5 min read

Ransomware group lists Nvidia on its leak site, but offers no proof

On 18 November 2026, the ransomware group The Gentlemen added Nvidia to its dark web leak site and set a countdown to 28 November. The listing contains no sample files, screenshots or data inventory. Nvidia says it is investigating an incident that may have affected a third-party partner, and that it has found no indication that its own systems or networks were affected. The claim is unverified.

Security 4 min read

Patch Splunk, and retire any internet-facing SonicWall Gen 6 firewall

On 18 November 2026, Splunk patched nearly 140 vulnerabilities in Enterprise, Enterprise Security and SOAR, including several critical flaws, with no active exploitation reported. SonicWall told customers to retire Gen 6 firewalls from the internet edge, as they no longer receive patches for any severity. Patch Splunk and replace Gen 6 devices.